OPERATION MANUALE2T QUASAR Flare MonitorsM8100PM-EXP • M8100FM-EXP • M8100SM-EXP
E2T QUASAR Flare Monitors Operation Manual General 101.6 Shipments to LumaSense for RepairAll RMA shipments of LumaSense Technologies instruments a
E2T QUASAR Flare Monitors Operation Manual Introduction 112 Introduction2.1 System OverviewThe Quasar 8100-EXP Pilot Monitor (PM), Flare Monitor (F
E2T QUASAR Flare Monitors Operation Manual Introduction 12A sight-through optical system and selection of various optical resolutions (fields of vi
E2T QUASAR Flare Monitors Operation Manual Introduction 132.3 Principle of OperationAll objects above absolute zero emit infrared energy. The amoun
E2T QUASAR Flare Monitors Operation Manual Introduction 142.4.2 PM: Pilot Monitor’s Flame Sensitive WavelengthThe QUASAR M8100PM-EXP uses a single
E2T QUASAR Flare Monitors Operation Manual Introduction 15Note: Secure power input lines together after connection to the Terminalblock to prevent
E2T QUASAR Flare Monitors Operation Manual Introduction 16To ensure consistent document formatting, this page was intentionally left blank.
E2T QUASAR Flare Monitors Operation Manual Mechanical Installation 173 Mechanical Installation3.1 Getting StartedEach LumaSense E2T QUASAR M8100-EX
E2T QUASAR Flare Monitors Operation Manual Mechanical Installation 183.2.2 Flare Monitor (FM) SightingRecommended installation distance should be e
E2T QUASAR Flare Monitors Operation Manual Mechanical Installation 19Figure 5: Pedestal Mounting Concept3.3 Ambient Temperature LimitsThe ambient o
E2T QUASAR Flare Monitors Operation Manual General iiConfidential InformationThe material contained herein consists of information that is the prop
E2T QUASAR Flare Monitors Operation Manual Mechanical Installation 20Note: The cooling cavity is isolated from internal surface of explosion-proof
E2T QUASAR Flare Monitors Operation Manual Mechanical Installation 21(1) Eyepiece Lens with ReticleFigure 6: Focus Adjustments(2) Focus adjust and
E2T QUASAR Flare Monitors Operation Manual Mechanical Installation 22To ensure consistent document formatting, this page was intentionally left bla
E2T QUASAR Flare Monitors Operation Manual Electrical Installation 234 Electrical Installation4.1 Electrical Installation GuidelinesBe sure to ref
E2T QUASAR Flare Monitors Operation Manual Electrical Installation 244.2.1 Service MarkingsInput Power service (i.e.120VAC, 220VAC, 24VDC) and Fus
E2T QUASAR Flare Monitors Operation Manual Electrical Installation 254.2.4 Powering with 115 Volts ACNote: Voltage/fusing are factory set. Use a
E2T QUASAR Flare Monitors Operation Manual Electrical Installation 264.3 Fusing4.3.1 MainsTwo fuses, F1 and F2, are each mounted within fuse holde
E2T QUASAR Flare Monitors Operation Manual Electrical Installation 274.5 Connecting the Set Point RelayThe set point relay provides a dry contact
E2T QUASAR Flare Monitors Operation Manual Electrical Installation 28To ensure consistent document formatting, this page was intentionally left bl
E2T QUASAR Flare Monitors Operation Manual Operating the M8100PM-EXP 295 Operating the M8100PM-EXPThis section covers the start-up procedures for
E2T QUASAR Flare Monitors Operation Manual General iiiContents1 General ...
E2T QUASAR Flare Monitors Operation Manual Operating the M8100PM-EXP 30Figure 8: Instrument Aiming Concept
E2T QUASAR Flare Monitors Operation Manual Operating the M8100PM-EXP 31 1. Eyepiece Lens with Reticle 2. Status Red LED: Alarm 3. Status G
E2T QUASAR Flare Monitors Operation Manual Operating the M8100PM-EXP 325.1.2 Initial Control Settings(Item numbers refer to and Figure 9: Opto-Ele
E2T QUASAR Flare Monitors Operation Manual Operating the M8100PM-EXP 335.1.6 Noise AmplificationOnce setup adjustments have been completed, confir
E2T QUASAR Flare Monitors Operation Manual Operating the M8100PM-EXP 345.1.8 Delay AdjustThe Delay Adjust (Figure 9, Item 9) can be configured fro
E2T QUASAR Flare Monitors Operation Manual Operating the M8100FM-EXP 356 Operating the M8100FM-EXPThis section covers the start-up procedures for
E2T QUASAR Flare Monitors Operation Manual Operating the M8100FM-EXP 36 1. Eyepiece Lens with Reticle 2. Status Red LED: Alarm 3. Status G
E2T QUASAR Flare Monitors Operation Manual Operating the M8100FM-EXP 376.1.2 Initial Control Settings(Item numbers refer to and Figure 11: Opto-El
E2T QUASAR Flare Monitors Operation Manual Operating the M8100FM-EXP 38the Pilot flame when the Flare is not present. Complete the procedure below
E2T QUASAR Flare Monitors Operation Manual Operating the M8100FM-EXP 39b. Verify that noise amplification has not returned. If the noise has retur
E2T QUASAR Flare Monitors Operation Manual General iv4.2.4 Powering with 115 Volts AC ...
E2T QUASAR Flare Monitors Operation Manual Operating the M8100FM-EXP 403. Adjust the System Gain no more than 2 turns counter-clockwise so that th
E2T QUASAR Flare Monitors Operation Manual Operating the M8100SM-EXP 417 Operating the M8100SM-EXPThis section covers the start-up procedures for
E2T QUASAR Flare Monitors Operation Manual Operating the M8100SM-EXP 42Figure 12: Instrument Aiming Concept
E2T QUASAR Flare Monitors Operation Manual Operating the M8100SM-EXP 43 1. Eyepiece Lens with Reticle 2. Status Red LED: Alarm 3. Status G
E2T QUASAR Flare Monitors Operation Manual Operating the M8100SM-EXP 447.1.2 Initial Control Settings(Item numbers refer to Figure 13)1. Adjust al
E2T QUASAR Flare Monitors Operation Manual Operating the M8100SM-EXP 457.1.7 Milliamp Output (+mA / -mA)The milliamp output to the control room is
E2T QUASAR Flare Monitors Operation Manual Operating the M8100SM-EXP 46MOST PREVALANT WORLD-WIDE STANDARDFLARE STACK VALUESOBSERVABLE DESCRIPTION
E2T QUASAR Flare Monitors Operation Manual Troubleshooting 478 Troubleshooting8.1 Problem Isolation Checkout ProcedureThis is an outline of what t
E2T QUASAR Flare Monitors Operation Manual Troubleshooting 48as it rotates. The output may produce a non-rising low reading even when looking at h
E2T QUASAR Flare Monitors Operation Manual Troubleshooting 498.1.7 Component FailureEvery QUASAR M8100-EXP is thermally cycled between 40 °F (4 °C
E2T QUASAR Flare Monitors Operation Manual General v8.1.3 Power Fuse ...
E2T QUASAR Flare Monitors Operation Manual Troubleshooting 50To ensure consistent document formatting, this page was intentionally left blank.
E2T QUASAR Flare Monitors Operation Manual Maintenance 519 Maintenance9.1 General MaintenanceRefer to Chapter 10, Safety Assurances and Precaution
E2T QUASAR Flare Monitors Operation Manual Maintenance 52To clean the objective lens, remove the electro-optical package from the explosion-proofe
E2T QUASAR Flare Monitors Operation Manual Safety Assurances and Precautions 5310 Safety Assurances and Precautions10.1 Hazardous Environment Safe
E2T QUASAR Flare Monitors Operation Manual Safety Assurances and Precautions 5410.2.3 Transient ProtectionTransients must not exceed 2.5kV between
E2T QUASAR Flare Monitors Operation Manual Appendix A: Specifications and ParameterSettings 55Appendix A: Specifications and ParameterSettingsTem
E2T QUASAR Flare Monitors Operation Manual Appendix A: Specifications and ParameterSettings 56Hazard Classification(See Appendix B, AreaClassific
E2T QUASAR Flare Monitors Operation Manual Appendix B: Area Classification/ProtectionConcepts 57Appendix B: Area Classification/ProtectionConcept
E2T QUASAR Flare Monitors Operation Manual Appendix B: Area Classification/ProtectionConcepts 58Contains the explosion, prevents flame propagatio
E2T QUASAR Flare Monitors Operation Manual Appendix B: Area Classification/ProtectionConcepts 59areas in the vicinity of spraying and painting op
E2T QUASAR Flare Monitors Operation Manual General viTo ensure consistent document formatting, this page was intentionally left blank.
E2T QUASAR Flare Monitors Operation Manual Appendix B: Area Classification/ProtectionConcepts 60centimeter. Dusts containing magnesium or aluminu
E2T QUASAR Flare Monitors Operation Manual Appendix C: Declaration of Conformity/Certificate 61Appendix C: Declaration of Conformity/Certificate
E2T QUASAR Flare Monitors Operation Manual Appendix C: Declaration of Conformity/Certificate 62
E2T QUASAR Flare Monitors Operation Manual Appendix C: Declaration of Conformity/Certificate 63
E2T QUASAR Flare Monitors Operation Manual Appendix C: Declaration of Conformity/Certificate 64ATEX KEMA Dekra CertificatePlease contact the facto
E2T QUASAR Flare Monitors Operation Manual Appendix D: Statement of Limited Warranty, NewInstruments 65Appendix D: Statement of LimitedWarranty, N
E2T QUASAR Flare Monitors Operation Manual Appendix D: Statement of Limited Warranty, NewInstruments 66To ensure consistent document formatting, t
E2T QUASAR Flare Monitors Operation Manual Appendix E: Engineering Drawings 67Appendix E: Engineering DrawingsPage Dwg.# Description68 613-107
E2T QUASAR Flare Monitors Operation Manual Appendix E: Engineering Drawings 68Drawing 613-107 E2T QUASAR M8100-EXP Appendix E
E2T QUASAR Flare Monitors Operation Manual Appendix E: Engineering Drawings 69Drawing 613-228 E2T QUASAR M8100-EXP Appendix E
E2T QUASAR Flare Monitors Operation Manual General 71 General1.1 Information about the user manualThis manual provides important information that c
E2T QUASAR Flare Monitors Operation Manual Appendix E: Engineering Drawings 70
E2T QUASAR Flare Monitors Operation Manual Appendix E: Engineering Drawings 71
E2T QUASAR Flare Monitors Operation Manual Appendix E: Engineering Drawings 72Drawing 613-812 E2T QUASAR M8100-EXP Appendix E
E2T QUASAR Flare Monitors Operation Manual Appendix E: Engineering Drawings 73
E2T QUASAR Flare Monitors Operation Manual Appendix E: Engineering Drawings 74Drawing 613-816 E2T QUASAR M8100-EXP Appendix E
E2T QUASAR Flare Monitors Operation Manual Appendix E: Engineering Drawings 75
E2T QUASAR Flare Monitors Operation Manual Appendix E: Engineering Drawings 76To ensure consistent document formatting, this page was intentionall
E2T QUASAR Flare Monitors Operation Manual Index 77Index44-20mA Outputs 13, 26AAccessories 12AGC Compensation 29, 35, 41Alarm Set Point 13Ambient T
E2T QUASAR Flare Monitors Operation Manual Index 78NNoise Amplification 33OObjective Lens 29, 35, 41Opto-Electronics Module 29, 35, 41Oscillation o
E2T QUASAR Flare Monitors Operation Manual General 81.2.1 Explosion Proof HousingThe housing is designed to meet the explosion-proof requirements o
E2T QUASAR Flare Monitors Operation Manual General 9When unpacking and inspecting your system, you need to do the following: Check all materials i
Comentarios a estos manuales