IMPAC pyrometers ISR 12-LO · IGAR 12-LO
5
Maximum value storage: Built-in single or double storage. Clearing with
adjusted time t
clear
(0.00 s; 0.01 s; 0.05 s; 0.25 s; 1 s; 5 s; 25 s), extern, via
interface or automatically with the next measuring object
Switch contact:
max. 0.15 A (only active with automatic clear mode or t
CL
0.5 s)
Measuring uncertainty:
(ε = 1, t
90
= 1 s, T
U
= 23°C)
ISR 12-LO: 0.4% of reading in °C + 1°C (< 1500°C)
0.6% of reading in °C + 1°C (> 1500°C)
IGAR 12-LO: 0.5% of reading in °C + 1°C (< 1500°C)
0.7% of reading in °C + 1°C (> 1500°C)
Repeatability: ISR 12-LO: 0.2% of reading in °C + 1°C
IGAR 12-LO: 0.3% of reading in °C + 1°C
Control panel: 4 function keys, switch for serial interface, push button for test current
Protection class: IP65 (DIN 40 050)
Ambient temperature: Converter housing: 0 to 60°C (ISR 12-LO); 0 to 50°C (IGAR 12-LO)
Storage temperature: -20 ... 70°C
Weight converter: 2.2 kg
Sighting: Laser targeting light (max. power level < 1 mW,
λ = 630-680 nm, CDRH class II).
(With IGAR 12-LO measurements are possible while
laser targeting light is switched on, with ISR 12-LO
measuring is stopped)
CE-label: According to EU directives about electromagnetic immunity
1.1 Dimensions
Py
rometer housing: Optical heads:
Type I (small optics):
Type II (focusable optics):
Type II (fixed adjusted):
all dimensions in mm