IMPAC pyrometers ISR 12-LO/GS
9
4.1 Pin assignment for the male socket on the bottom side of the pyrometer
Pin Color Indication
K white + 24 V power supply (or 24 V AC) (12 ... 30 V)
A brown 0 V power supply
L green
+ I
outp.
analog output
B yellow
– I
outp.
analog output
H gray external switch for targeting light (bridge to K)
J pink
see 4.1.1: output for operating mode contact,
external clearing of maximum value storage,
lens contamination monitoring or extern hold
G red DGND (Ground for interface)
F black RxD (RS232) or B1 (RS485)
C violet TxD (RS232) or A1 (RS485)
D gray/pink RxD (RS232) or B2 (RS485) (bridge to F)
E red/blue TxD (RS232) or A2 (RS485) (bridge to C)
M orange
Screen only for cable extension,
don’t connect at the switchboard
4.1.1 Connector pin J
The co
nnector pin J can be used for 4 different functions:
1) Operating mode contact: During the warm-up of the pyrometer (after connection to the power supply,
the LED display on the converter indicates “7777”) pin J is connected to the power supply voltage. This volt-
age is connected by a relays switch (max. continuous current 0.4 A) to pin K (power supply voltage). This
relays switch opens when the warm-up is finished and the pyrometer is in operating mode. For that reason
this pin can be used as operating mode contact.
2) External clearing of the maximum value storage: When the pyrometer is in operating mode, pin J can
be used for external clearing of maximum value storage (see 8.4). To
clear the maximum value storage,
connect pin J for a short time to pin K (power supply voltage).
The function “external clearing” is activated with the following conditions:
Warm-up is finished (no display “7777“)
The clear time is set to “extern“ (see 8.4, 9.7).
The lens contamination monitoring is switched off. This can be done via software InfraWin in “color-bar“
window. The warning level “dirty window” must be set to 0% (see 9.8).
3) Len
s contamination monitoring system: The pyrometers are equipped with a contamination monitoring
system. Contamination of lens or sighting window or dust in the sighting path of the pyrometer can interfere
the signal in such a high level that a correct temperature measurement will be impossible (this can also hap-
pen if the object is smaller than the spot size of the pyrometer). To avoid wrong measurements in advance, a
warning signal can be set to a certain contamination level. If contamination reaches this level (or at a certain
too low signal level), a built-in relays (max. continuous current 0.4 A) connects pin J to pin K (power supply
voltage). The setting of the switch level (0 … 99%) can be done via software InfraWin in “color-bar“ window.
If the warning level “dirty window” is set to 0% (see 9.8) the lens
contamination monitoring system is
switched off and pin J has the function “external clearing” of maximum value storage (factory setting).
The lens contamination monitoring system is activated with the following conditions:
Warm-up is finished (no display “7777“)
The clear time is not set to “extern“ or “hold” (see 8.4, 9.7).
The pyrometer is operating in “2-color mode” (see 8.5, 9.7)
4) Extern Hold: Whe
n the hold function mode is activated the current pouring stream temperature (or the
current temperature reading if the instrument is not in pouring stream mode) is frozen as long as J and pin K
are connected (see 8.4 clear time of the maximum value storage).
K
A
B
C
D
J
G F E
H
M
L
Connector
Pin assignment
(side of male inserts)
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 59 60

Comentarios a estos manuales

Sin comentarios